User Tools

Site Tools


hp:ssacli

This is an old revision of the document!


ssacli

Примеры использования HP Enterprise ssacli

Ссылка на ssacli https://downloads.linux.hpe.com/SDR/project/mcp/

Show configuration

''ssacli ctrl all show config
''

Controller status

''ssacli ctrl all show status
''

Show detailed controller information for all controllers

''ssacli ctrl all show detail
''

Show detailed controller information for controller in slot 0

''ssacli ctrl slot=0 show detail
''

Rescan for New Devices

''ssacli rescan
''

Physical disk status

''ssacli ctrl slot=0 pd all show status
''

Show detailed physical disk information

''ssacli ctrl slot=0 pd all show detail
''

Logical disk status

''ssacli ctrl slot=0 ld all show status
''

View Detailed Logical Drive Status

''ssacli ctrl slot=0 ld 2 show
''

Create New RAID 0 Logical Drive

''ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
''

Create New RAID 1 Logical Drive

''ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
''

Create New RAID 5 Logical Drive

''ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
''

Delete Logical Drive

''ssacli ctrl slot=0 ld 2 delete
''

Add New Physical Drive to Logical Volume

''ssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
''

Add Spare Disks

''ssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
''

Enable Drive Write Cache

''ssacli ctrl slot=0 modify dwc=enable
''

Disable Drive Write Cache

''ssacli ctrl slot=0 modify dwc=disable
''

Erase Physical Drive

''ssacli ctrl slot=0 pd 2I:1:6 modify erase
''
''ssacli ctrl slot=0 ld 2 modify led=on
''
''ssacli ctrl slot=0 ld 2 modify led=off
''

Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)

''ssacli ctrl slot=0 modify cacheratio=100/0
''

Enable smart array write cache when no battery is present (No-Battery Write Cache option)

''ssacli ctrl slot=0 modify nbwc=enable
''

Disable smart array cache for certain Logical Volume

''ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
''

Enable smart array cache for certain Logical Volume

''ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
''

Enable SSD Smart Path

''ssacli ctrl slot=0 array a modify ssdsmartpath=enable
''

Disable SSD Smart Path

''ssacli ctrl slot=0 array a modify ssdsmartpath=disable''